Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
31mm
Length of sensor
33.5mm
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at DC-13, 24 V
3A
Rated operation current Ie at AC-15, 230 V
6A
Height of sensor
86mm
Rated operation current Ie at AC-15, 24 V
6A
Switching function latching
No
Diameter sensor
0mm
Forced opening
Yes
Switching function
Slow-action switch
Rated operation current Ie at DC-13, 230 V
0.3A
Number of safety auxiliary contacts
2
Output electronic
No
Type of interface
None
Number of contacts as normally closed contact
2
Number of contacts as change-over contact
0
Rated operation current Ie at DC-13, 125 V
0.6A
Material housing
Plastic
Coating housing
Other
Number of contacts as normally open contact
0
Type of control element
Plunger
Suitable for safety functions
Yes
Ambient temperature during operating
-25 - 70°C
Alignment of the control element
Roller cam straight
Type of electric connection
Connector M12
With status indication
No
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP66
Construction type housing
Cuboid
Explosion safety category for dust
None
Explosion safety category for gas
None
Type of interface for safety communication
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LS-02-M12A

Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
31mm
Length of sensor
33.5mm
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at DC-13, 24 V
3A
Rated operation current Ie at AC-15, 230 V
6A
Height of sensor
86mm
Rated operation current Ie at AC-15, 24 V
6A
Switching function latching
Diameter sensor
0mm
Forced opening
Switching function
Slow-action switch
Rated operation current Ie at DC-13, 230 V
0.3A
Number of safety auxiliary contacts
2
Output electronic
Type of interface
None
Number of contacts as normally closed contact
2
Number of contacts as change-over contact
0
Rated operation current Ie at DC-13, 125 V
0.6A
Material housing
Plastic
Coating housing
Other
Number of contacts as normally open contact
0
Type of control element
Plunger
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
Alignment of the control element
Roller cam straight
Type of electric connection
Connector M12
With status indication
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP66
Construction type housing
Cuboid
Explosion safety category for dust
None
Explosion safety category for gas
None
Type of interface for safety communication
None
From same serie