Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as emergency stop installation
No
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Version as safety switch
No
Max. rated operation voltage Ue AC
1000V
Number of switches
1
Version as reversing switch
No
Rated operating voltage
1000 - 1000V
Rated permanent current Iu
100A
Rated permanent current at AC-23, 400 V
0A
Rated short-time withstand current lcw
3kA
Rated operation power at AC-3, 400 V
0kW
Conditioned rated short-circuit current Iq
0kA
Switching power at 400 V
0kW
Number of poles
2
Rated permanent current at AC-21, 400 V
0A
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Motor drive optional
No
Rated operation power at AC-23, 400 V
0kW
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting centre
No
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Colour control element
Grey
Device construction
Complete device in housing
Type of electrical connection of main circuit
Screw connection
Suitable for distribution board installation
No
Voltage release optional
No
Suitable for intermediate mounting
No
Type of control element
Door coupling rotary drive
Interlockable
Yes
With pre-assembled cabling
No
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Depth
280mm
Width
200mm
Height
160mm
From same serie
DDC-100/2/I5/P-G

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as emergency stop installation
Version as maintenance-/service switch
Version as main switch
Version as safety switch
Max. rated operation voltage Ue AC
1000V
Number of switches
1
Version as reversing switch
Rated operating voltage
1000 .. 1000V
Rated permanent current Iu
100A
Rated permanent current at AC-23, 400 V
0A
Rated short-time withstand current lcw
3kA
Rated operation power at AC-3, 400 V
0kW
Conditioned rated short-circuit current Iq
0kA
Switching power at 400 V
0kW
Number of poles
2
Rated permanent current at AC-21, 400 V
0A
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Motor drive optional
Rated operation power at AC-23, 400 V
0kW
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting centre
Suitable for floor mounting
Suitable for front mounting 4-hole
Colour control element
Grey
Device construction
Complete device in housing
Type of electrical connection of main circuit
Screw connection
Suitable for distribution board installation
Voltage release optional
Suitable for intermediate mounting
Type of control element
Door coupling rotary drive
Interlockable
With pre-assembled cabling
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Depth
280mm
Width
200mm
Height
160mm