Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Cable type
Other
Duplex
No
Nominal cross section conductor
0.5mm²
Number of stranding elements
5
Conductor category
Class 2 = stranded
Stranding element
Pairs
Diameter conductor
1.5mm
Screen over stranding
None
Core identification
Colour
Longitudinal water blocking cable
Yes
Material core insulation
Other
Radial water blocking cable
Yes
Conductor material
Other
Approved type of underground installation
Other
Stranding
Bundle
Suitable for underground installation
No
Material outer sheath
Polyvinyl chloride (PVC)
Protective sheath
Other
Armouring/reinforcement
None
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Cable geometry
Round
Flame retardant according to IEC 60332-1-2
No
Low smoke (according to IEC 61034-2)
No
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Specification material outer sheath
Polypropylene (PP)
Smoke development class according to EN 13501-6
None
Core identification according to HD 308 S2
No
Euro class flaming droplets/particles according to EN 13501-6
None
Specification core insulation
Other
Colour outer sheath
Green
Outer diameter approx.
5.6mm
Halogen free according to IEC 60754-3
No
Conductor surface
Bare
AWG size
20
Number of sheath layers
0
Number of cores
5
Screen over stranding element
Foil
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Min. permitted bending radius, moving application/free movement
46mm
Min. permitted bending radius, moving application with forced guidance
46mm
Euro class acidity according to EN 13501-6
None
Material reinforcement
Other
Reaction-to-fire class according to EN 13501-6
None
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Circuit integrity according to IEC 60331-23
No
Halogen free according to IEC 60754-1
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Min. permitted bending radius, stationary application/permanent installation
34mm
Halogen free (according to IEC 60754-2)
No
Oil resistant (according to EN 60811-404)
Yes
Permitted cable outer temperature during assembling/handling
-40 - 80°C
UV resistant
Yes
Certified for shipboard application
No
Permitted cable outer temperature after assembling without vibration
-40 - 80°C
Category
Other
NVP value
66.5%
Suitable as signalling cable
Yes
Suitable for use as security alarm cable
No
Suitable as telephone cable
No
Cable height approx.
16.3mm
Suitable as computer data cable
No
Drain wire
No
With rip cord
No
Cable width approx.
5.6mm
Characteristic impedance
100Ohm
With rodent protection
No
Nominal voltage U
24V
Compatible with Grade3TV according to XP-C 90-483
No
Compatible with Grade2TV according to XP-C 90-483
No
From same serie
SWD4-1M5LR5-2S

Details
- Cables
- Data and communication cable
- 1 KOM
- EATON
Technical specifications
Cable type
Other
Duplex
Nominal cross section conductor
0.5mm²
Number of stranding elements
5
Conductor category
Class 2 = stranded
Stranding element
Pairs
Diameter conductor
1.5mm
Screen over stranding
None
Core identification
Colour
Longitudinal water blocking cable
Material core insulation
Other
Radial water blocking cable
Conductor material
Other
Approved type of underground installation
Other
Stranding
Bundle
Suitable for underground installation
Material outer sheath
Polyvinyl chloride (PVC)
Protective sheath
Other
Armouring/reinforcement
None
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
Cable geometry
Round
Flame retardant according to IEC 60332-1-2
Low smoke (according to IEC 61034-2)
Flame retardant according to IEC 60332-3-24 (Cat C)
Specification material outer sheath
Polypropylene (PP)
Smoke development class according to EN 13501-6
None
Core identification according to HD 308 S2
Euro class flaming droplets/particles according to EN 13501-6
None
Specification core insulation
Other
Colour outer sheath
Green
Outer diameter approx.
5.6mm
Halogen free according to IEC 60754-3
Conductor surface
Bare
AWG size
20
Number of sheath layers
0
Number of cores
5
Screen over stranding element
Foil
Flame retardant according to IEC 60332-3-22 (Cat A)
Min. permitted bending radius, moving application/free movement
46mm
Min. permitted bending radius, moving application with forced guidance
46mm
Euro class acidity according to EN 13501-6
None
Material reinforcement
Other
Reaction-to-fire class according to EN 13501-6
None
Flame retardant according to IEC 60332-3-23 (Cat B)
Circuit integrity according to IEC 60331-23
Halogen free according to IEC 60754-1
Flame retardant according to IEC 60332-3-25 (Cat D)
Min. permitted bending radius, stationary application/permanent installation
34mm
Halogen free (according to IEC 60754-2)
Oil resistant (according to EN 60811-404)
Permitted cable outer temperature during assembling/handling
-40 .. 80°C
UV resistant
Certified for shipboard application
Permitted cable outer temperature after assembling without vibration
-40 .. 80°C
Category
Other
NVP value
66.5%
Suitable as signalling cable
Suitable for use as security alarm cable
Suitable as telephone cable
Cable height approx.
16.3mm
Suitable as computer data cable
Drain wire
With rip cord
Cable width approx.
5.6mm
Characteristic impedance
100Ohm
With rodent protection
Nominal voltage U
24V
Compatible with Grade3TV according to XP-C 90-483
Compatible with Grade2TV according to XP-C 90-483