Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
No
Nominal voltage DC
585V
System configuration TT
No
System configuration TN-S
No
System configuration TN-C-S
No
Nominal voltage AC
0V
Nominal discharge surge current (8/20)
15kA
System configuration DC
No
Short-circuit breaking capacity (Isccr)
0kA
System configuration IT
Yes
Integrated backup fuse
No
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. conductor cross section solid (solid, stranded)
0mm²
Voltage protection level N-PE
0kV
Number of conductors (without earthing)
0
Max. overcurrent protection device, series connection (fuse)
0A
Signalling at the device
Optic
Category type 2
Yes
Max. continuous voltage AC
0V
Degree of protection (IP)
IP20
Max. discharge surge current (8/20)
40kA
System configuration other
No
With remote signalling contact
No
Integrated short-circuit protection selective to fuse gG
0A
Max. PV-voltage
585V
Max. continuous voltage DC
585V
Mounting method
On basic element
Voltage protection level L-N
0kV
Leakage-current free
No
Max. conductor cross section flexible (fine-strand)
0mm²
Voltage protection level
1.9kV
Construction size
1 modular spacing
Integrated short-circuit protection
No
System configuration TN
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPPVT2-10

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
Nominal voltage DC
585V
System configuration TT
System configuration TN-S
System configuration TN-C-S
Nominal voltage AC
0V
Nominal discharge surge current (8/20)
15kA
System configuration DC
Short-circuit breaking capacity (Isccr)
0kA
System configuration IT
Integrated backup fuse
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. conductor cross section solid (solid, stranded)
0mm²
Voltage protection level N-PE
0kV
Number of conductors (without earthing)
0
Max. overcurrent protection device, series connection (fuse)
0A
Signalling at the device
Optic
Category type 2
Max. continuous voltage AC
0V
Degree of protection (IP)
IP20
Max. discharge surge current (8/20)
40kA
System configuration other
With remote signalling contact
Integrated short-circuit protection selective to fuse gG
0A
Max. PV-voltage
585V
Max. continuous voltage DC
585V
Mounting method
On basic element
Voltage protection level L-N
0kV
Leakage-current free
Max. conductor cross section flexible (fine-strand)
0mm²
Voltage protection level
1.9kV
Construction size
1 modular spacing
Integrated short-circuit protection
System configuration TN
From same serie
We use cookies to enhance your experience.