Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated voltage
1000 - 1000V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range undelayed short-circuit release
800 - 4400A
Device construction
Built-in device fixed built-in technique
Rated permanent current Iu
400A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Overload release current setting
200 - 400A
Type of electrical connection of main circuit
Screw connection
Adjustment range short-term delayed short-circuit release
400 - 4000A
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
No
With integrated under voltage release
No
Motor drive integrated
No
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Number of poles
3
Type of control element
Rocker lever
Degree of protection (IP)
IP20
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMH3-VE400-S1

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated voltage
1000 .. 1000V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range undelayed short-circuit release
800 .. 4400A
Device construction
Built-in device fixed built-in technique
Rated permanent current Iu
400A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Overload release current setting
200 .. 400A
Type of electrical connection of main circuit
Screw connection
Adjustment range short-term delayed short-circuit release
400 .. 4000A
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
With integrated under voltage release
Motor drive integrated
DIN rail (top hat rail) mounting optional
Motor drive optional
Number of poles
3
Type of control element
Rocker lever
Degree of protection (IP)
IP20
Complete device with protection unit
From same serie
Related products