Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range short-term delayed short-circuit release
0 - 0A
Overload release current setting
400 - 500A
Adjustment range undelayed short-circuit release
6 - 10A
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
500A
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Rated voltage
690 - 690V
Motor drive optional
Yes
Position of connection for main current circuit
Front side
With integrated under voltage release
No
Degree of protection (IP)
IP20
Complete device with protection unit
Yes
Motor drive integrated
No
Type of control element
Rocker lever
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMC3-4-A500/320-AVE

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range short-term delayed short-circuit release
0 .. 0A
Overload release current setting
400 .. 500A
Adjustment range undelayed short-circuit release
6 .. 10A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
500A
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of poles
4
Rated voltage
690 .. 690V
Motor drive optional
Position of connection for main current circuit
Front side
With integrated under voltage release
Degree of protection (IP)
IP20
Complete device with protection unit
Motor drive integrated
Type of control element
Rocker lever
From same serie
Related products