Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Length of sensor
33.5mm
Height of sensor
61mm
Diameter sensor
0mm
Width sensor
31mm
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at AC-15, 24 V
6A
Switching function
Slow-action switch
Rated operation current Ie at DC-13, 125 V
0.8A
Number of contacts as change-over contact
0
Rated operation current Ie at DC-13, 24 V
3A
Switching function latching
No
Material housing
Plastic
Type of interface for safety communication
None
Forced opening
Yes
Rated operation current Ie at DC-13, 230 V
0.3A
Output electronic
No
Number of safety auxiliary contacts
1
Coating housing
Other
Construction type housing
Cuboid
Alignment of the control element
Roller cam straight
With status indication
No
Number of contacts as normally closed contact
1
Suitable for safety functions
Yes
Type of electric connection
Cable entry metrical
Type of control element
Plunger
Number of contacts as normally open contact
1
Type of interface
None
Explosion safety category for gas
None
Explosion safety category for dust
None
Degree of protection (IP)
IP65
Ambient temperature during operating
-40 - 70°C
Degree of protection (NEMA)
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LS-S11-CC

Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Length of sensor
33.5mm
Height of sensor
61mm
Diameter sensor
0mm
Width sensor
31mm
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at AC-15, 24 V
6A
Switching function
Slow-action switch
Rated operation current Ie at DC-13, 125 V
0.8A
Number of contacts as change-over contact
0
Rated operation current Ie at DC-13, 24 V
3A
Switching function latching
Material housing
Plastic
Type of interface for safety communication
None
Forced opening
Rated operation current Ie at DC-13, 230 V
0.3A
Output electronic
Number of safety auxiliary contacts
1
Coating housing
Other
Construction type housing
Cuboid
Alignment of the control element
Roller cam straight
With status indication
Number of contacts as normally closed contact
1
Suitable for safety functions
Type of electric connection
Cable entry metrical
Type of control element
Plunger
Number of contacts as normally open contact
1
Type of interface
None
Explosion safety category for gas
None
Explosion safety category for dust
None
Degree of protection (IP)
IP65
Ambient temperature during operating
-40 .. 70°C
Degree of protection (NEMA)
Other
From same serie