Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Disconnection characteristic

Undelayed

Release characteristic

D

Surge current capacity

0.25kA

Number of poles (total)

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Yes

Leakage current type

AC

Over voltage category

3

With interlocking device

No

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section multi-wired

1 - 25mm²

Anti-nuisance tripping version

No

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated fault current

0.03A

Number of protected poles

1

Voltage type

AC

Width in number of modular spacings

2

Pollution degree

2

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated current

6A

Current limiting class

3

Frequency

50 Hz

Connectable conductor cross section solid-core

1 - 25mm²

Flush-mounted installation

No

Built-in depth

75.5mm

Ambient temperature during operating

-25 - 40°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FRBmM-D6/1N/003

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Disconnection characteristic

Undelayed

Release characteristic

D

Surge current capacity

0.25kA

Number of poles (total)

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Leakage current type

AC

Over voltage category

3

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated fault current

0.03A

Number of protected poles

1

Voltage type

AC

Width in number of modular spacings

2

Pollution degree

2

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated current

6A

Current limiting class

3

Frequency

50 Hz

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Built-in depth

75.5mm

Ambient temperature during operating

-25 .. 40°C

From same serie