Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated fault current

0.1A

Current limiting class

3

Rated current

16A

Voltage type

AC

Surge current capacity

0.25kA

With interlocking device

No

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

No

Width in number of modular spacings

2

Ambient temperature during operating

-25 - 40°C

Rated voltage

240V

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Frequency

50 Hz

Release characteristic

B

Over voltage category

3

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Short-time delayed

Built-in depth

75.5mm

Flush-mounted installation

No

Connectable conductor cross section solid-core

1 - 25mm²

Degree of protection (IP)

IP20

Anti-nuisance tripping version

No

Connectable conductor cross section multi-wired

1 - 25mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FRBmM-B16/2/01-LIA

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated fault current

0.1A

Current limiting class

3

Rated current

16A

Voltage type

AC

Surge current capacity

0.25kA

With interlocking device

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Rated voltage

240V

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Frequency

50 Hz

Release characteristic

B

Over voltage category

3

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Short-time delayed

Built-in depth

75.5mm

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

1 .. 25mm²