Aleta.hr
Main Product Image

FAZ-D6/3-NA

Code: 1635739

ManufacturerRAZNO
Catalog number102264
Type
EAN code4015081021406

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated voltage

415V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Release characteristic

D

Number of protected poles

3

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated current

6A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

No

Over voltage category

3

Flush-mounted installation

No

Power loss

3.6W

Additional equipment possible

Yes

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Width in number of modular spacings

3

Frequency

50 - 60Hz

Connectable conductor cross section multi-wired

1 - 25mm²

Pollution degree

2

Connectable conductor cross section solid-core

1 - 25mm²

Ambient temperature during operating

-25 - 75°C

Explosion-proof

No

Degree of protection (IP)

IP20

Current limiting class

3


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-D6/3-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated voltage

415V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Release characteristic

D

Number of protected poles

3

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated current

6A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

Over voltage category

3

Flush-mounted installation

Power loss

3.6W

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Width in number of modular spacings

3

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Degree of protection (IP)

IP20

Current limiting class

3

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.