Aleta.hr
Main Product Image

FAZ-D5/3-RT

Code: 1635726

ManufacturerRAZNO
Catalog number102303
Type
EAN code4015081021796

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Release characteristic

D

Number of protected poles

3

Rated voltage

415V

Rated current

5A

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Voltage type

AC

Power loss

4.5W

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Pollution degree

2

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 75°C

Connectable conductor cross section solid-core

1 - 25mm²

Connectable conductor cross section multi-wired

1 - 25mm²

Flush-mounted installation

No

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-D5/3-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Release characteristic

D

Number of protected poles

3

Rated voltage

415V

Rated current

5A

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Voltage type

AC

Power loss

4.5W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

Additional equipment possible

Pollution degree

2

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Explosion-proof