Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Digital inputs configurable
Yes
Number of digital outputs
2
Voltage type of supply voltage
DC
Type of output voltage
DC
Type of voltage (input voltage)
DC
Output current
0.5A
Input current at signal 1
4mA
Supply voltage AC 60 Hz
0 - 0V
Number of HW-interfaces RS-422
0
Supply voltage AC 50 Hz
0 - 0V
Permitted voltage at input
20.4 - 28.8V
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for TCP/IP
No
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of digital inputs
2
Supply voltage DC
0 - 28.8V
With optical interface
No
Permitted voltage at output
20.4 - 28.8V
Number of HW-interfaces other
0
Supporting protocol for EtherCAT
No
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS
No
Supporting protocol for LON
No
Supporting protocol for KNX
No
Number of HW-interfaces serial TTY
0
Supporting protocol for SUCONET
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIsafe
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
Yes
Short-circuit protection, outputs available
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFIBUS
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces Wireless
0
Type of digital output
Other
Number of HW-interfaces RS-485
0
Digital outputs configurable
Yes
Supporting protocol for SafetyBUS p
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET IO
No
Number of interfaces PROFINET
0
Supporting protocol for DeviceNet
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Radio standard GSM
No
Radio standard GPRS
No
Radio standard UMTS
No
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP69K
Type of electric connection
Screw connection
Time delay at signal exchange
0 - 0.2ms
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Suitable for safety functions
No
Rack-assembly possible
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
SIL according to IEC 61508
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Explosion safety category for gas
None
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
56.9mm
Depth
85.6mm
Height
20.1mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
EU1E-SWD-2DD

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Digital inputs configurable
Number of digital outputs
2
Voltage type of supply voltage
DC
Type of output voltage
DC
Type of voltage (input voltage)
DC
Output current
0.5A
Input current at signal 1
4mA
Supply voltage AC 60 Hz
0 .. 0V
Number of HW-interfaces RS-422
0
Supply voltage AC 50 Hz
0 .. 0V
Permitted voltage at input
20.4 .. 28.8V
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for TCP/IP
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of digital inputs
2
Supply voltage DC
0 .. 28.8V
With optical interface
Permitted voltage at output
20.4 .. 28.8V
Number of HW-interfaces other
0
Supporting protocol for EtherCAT
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS
Supporting protocol for LON
Supporting protocol for KNX
Number of HW-interfaces serial TTY
0
Supporting protocol for SUCONET
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Short-circuit protection, outputs available
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIBUS
Number of HW-interfaces RS-232
0
Number of HW-interfaces Wireless
0
Type of digital output
Other
Number of HW-interfaces RS-485
0
Digital outputs configurable
Supporting protocol for SafetyBUS p
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Number of interfaces PROFINET
0
Supporting protocol for DeviceNet
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Radio standard GSM
Radio standard GPRS
Radio standard UMTS
IO link master
System accessory
Degree of protection (IP)
IP69K
Type of electric connection
Screw connection
Time delay at signal exchange
0 .. 0.2ms
Fieldbus connection over separate bus coupler possible
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Suitable for safety functions
Rack-assembly possible
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
SIL according to IEC 61508
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
Explosion safety category for gas
None
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 2
Certified for UL hazardous location division 1
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
56.9mm
Depth
85.6mm
Height
20.1mm
From same serie
Related products
We use cookies to enhance your experience.