Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Number of switches
1
Rated operating voltage
690 - 690V
Rated permanent current Iu
160A
Version as reversing switch
No
Version as emergency stop installation
Yes
Rated short-time withstand current lcw
2.5kA
Version as safety switch
No
Switching power at 400 V
0kW
Conditioned rated short-circuit current Iq
50kA
Rated operation power at AC-23, 400 V
80kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
140A
Motor drive optional
No
Number of poles
4
Max. rated operation voltage Ue AC
690V
Motor drive integrated
No
Rated operation power at AC-3, 400 V
0kW
Rated permanent current at AC-21, 400 V
160A
Number of auxiliary contacts as normally closed contact
0
Voltage release optional
No
Suitable for distribution board installation
No
Type of control element
Short thumb-grip
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
No
Degree of protection (NEMA)
12
With pre-assembled cabling
No
Suitable for floor mounting
Yes
Degree of protection (IP), front side
IP65
Width
200mm
Type of electrical connection of main circuit
Screw connection
Colour control element
Red
Height
200mm
Depth
280mm
Device construction
Complete device in housing
Interlockable
Yes
From same serie
DMM-160/4/I5/P-R

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Version as main switch
Number of switches
1
Rated operating voltage
690 .. 690V
Rated permanent current Iu
160A
Version as reversing switch
Version as emergency stop installation
Rated short-time withstand current lcw
2.5kA
Version as safety switch
Switching power at 400 V
0kW
Conditioned rated short-circuit current Iq
50kA
Rated operation power at AC-23, 400 V
80kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
140A
Motor drive optional
Number of poles
4
Max. rated operation voltage Ue AC
690V
Motor drive integrated
Rated operation power at AC-3, 400 V
0kW
Rated permanent current at AC-21, 400 V
160A
Number of auxiliary contacts as normally closed contact
0
Voltage release optional
Suitable for distribution board installation
Type of control element
Short thumb-grip
Suitable for front mounting centre
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Degree of protection (NEMA)
12
With pre-assembled cabling
Suitable for floor mounting
Degree of protection (IP), front side
IP65
Width
200mm
Type of electrical connection of main circuit
Screw connection
Colour control element
Red
Height
200mm
Depth
280mm
Device construction
Complete device in housing
Interlockable
From same serie