Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Number of switches
1
Rated operation power at AC-23, 400 V
0kW
Rated short-time withstand current lcw
15kA
Number of auxiliary contacts as normally open contact
2
Version as emergency stop installation
No
Version as main switch
Yes
Rated permanent current Iu
630A
Number of poles
2
Rated operating voltage
690 - 690V
Rated operation power at AC-3, 400 V
0kW
Motor drive optional
No
Number of auxiliary contacts as change-over contact
0
Conditioned rated short-circuit current Iq
0kA
Rated permanent current at AC-23, 400 V
0A
Max. rated operation voltage Ue AC
1000V
Switching power at 400 V
0kW
Number of auxiliary contacts as normally closed contact
2
Rated permanent current at AC-21, 400 V
0A
Version as safety switch
No
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
No
Motor drive integrated
No
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
No
Colour control element
Other
Interlockable
No
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Type of control element
Other
Degree of protection (NEMA)
Other
With pre-assembled cabling
No
Suitable for front mounting centre
No
Voltage release optional
No
Suitable for floor mounting
Yes
Width
127mm
Depth
240mm
Height
129mm
From same serie
DDC-630/2-SK

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Version as reversing switch
Number of switches
1
Rated operation power at AC-23, 400 V
0kW
Rated short-time withstand current lcw
15kA
Number of auxiliary contacts as normally open contact
2
Version as emergency stop installation
Version as main switch
Rated permanent current Iu
630A
Number of poles
2
Rated operating voltage
690 .. 690V
Rated operation power at AC-3, 400 V
0kW
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Conditioned rated short-circuit current Iq
0kA
Rated permanent current at AC-23, 400 V
0A
Max. rated operation voltage Ue AC
1000V
Switching power at 400 V
0kW
Number of auxiliary contacts as normally closed contact
2
Rated permanent current at AC-21, 400 V
0A
Version as safety switch
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
Motor drive integrated
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Colour control element
Other
Interlockable
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Type of control element
Other
Degree of protection (NEMA)
Other
With pre-assembled cabling
Suitable for front mounting centre
Voltage release optional
Suitable for floor mounting
Width
127mm
Depth
240mm
Height
129mm
From same serie