Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Yes
Version as safety switch
No
Version as maintenance-/service switch
Yes
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
1000V
Version as reversing switch
No
Number of switches
1
Rated permanent current at AC-23, 400 V
0A
Rated permanent current Iu
200A
Rated operation power at AC-3, 400 V
0kW
Rated permanent current at AC-21, 400 V
0A
Rated short-time withstand current lcw
4kA
Number of auxiliary contacts as normally closed contact
2
Conditioned rated short-circuit current Iq
0kA
Rated operating voltage
1000 - 1000V
Motor drive optional
No
Switching power at 400 V
0kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
2
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Rated operation power at AC-23, 400 V
0kW
Suitable for distribution board installation
No
Number of poles
2
Suitable for front mounting centre
No
Suitable for intermediate mounting
No
Colour control element
Other
Interlockable
No
Type of control element
Other
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
No
Degree of protection (NEMA)
Other
Degree of protection (IP), front side
IP20
Depth
160mm
Height
98mm
Width
83mm
From same serie
DDC-200/2-SK

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as safety switch
Version as maintenance-/service switch
Version as emergency stop installation
Max. rated operation voltage Ue AC
1000V
Version as reversing switch
Number of switches
1
Rated permanent current at AC-23, 400 V
0A
Rated permanent current Iu
200A
Rated operation power at AC-3, 400 V
0kW
Rated permanent current at AC-21, 400 V
0A
Rated short-time withstand current lcw
4kA
Number of auxiliary contacts as normally closed contact
2
Conditioned rated short-circuit current Iq
0kA
Rated operating voltage
1000 .. 1000V
Motor drive optional
Switching power at 400 V
0kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
2
Voltage release optional
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Suitable for floor mounting
Suitable for front mounting 4-hole
Rated operation power at AC-23, 400 V
0kW
Suitable for distribution board installation
Number of poles
2
Suitable for front mounting centre
Suitable for intermediate mounting
Colour control element
Other
Interlockable
Type of control element
Other
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
Degree of protection (NEMA)
Other
Degree of protection (IP), front side
IP20
Depth
160mm
Height
98mm
Width
83mm