Aleta.hr
Main Product Image

AZ-3N-B100

Code: 1632834

ManufacturerRAZNO
Catalog number174526
Type
EAN code4015081709823

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Number of poles (total)

4

Release characteristic

B

Rated current

100A

Number of protected poles

3

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Voltage type

AC

Pollution degree

2

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Current limiting class

3

Flush-mounted installation

No

Concurrently switching neutral conductor

Yes

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 55°C

Over voltage category

3

Connectable conductor cross section solid-core

2.5 - 50mm²

Connectable conductor cross section multi-wired

2.5 - 50mm²

Width in number of modular spacings

6

Additional equipment possible

Yes

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

AZ-3N-B100

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Number of poles (total)

4

Release characteristic

B

Rated current

100A

Number of protected poles

3

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Voltage type

AC

Pollution degree

2

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Connectable conductor cross section solid-core

2.5 .. 50mm²

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Width in number of modular spacings

6

Additional equipment possible

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.