Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated voltage

400V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of poles (total)

2

Release characteristic

B

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Built-in depth

75mm

Rated current

63A

Rated insulation voltage Ui

440V

Pollution degree

2

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Yes

Flush-mounted installation

No

Connectable conductor cross section solid-core

2.5 - 50mm²

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Over voltage category

3

Concurrently switching neutral conductor

No

Connectable conductor cross section multi-wired

2.5 - 50mm²

Explosion-proof

No

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 55°C

Frequency

50 - 60Hz


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

AZ-2-B63

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated voltage

400V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of poles (total)

2

Release characteristic

B

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Built-in depth

75mm

Rated current

63A

Rated insulation voltage Ui

440V

Pollution degree

2

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section solid-core

2.5 .. 50mm²

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Explosion-proof

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.