Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Rated voltage
1150 - 1150V
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Adjustment range undelayed short-circuit release
480.0 - 3840A
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
192.0 - 3200A
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Number of poles
3
With switched-off indicator
No
Type of control element
Toggle
Overload release current setting
128.0 - 320A
Degree of protection (IP)
IP20
Motor drive integrated
No
Motor drive optional
Yes
Rated permanent current Iu
400A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA063488R1 | T5V400 PR222DS/P-LSIG In320 3pFF

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Rated voltage
1150 .. 1150V
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Adjustment range undelayed short-circuit release
480.0 .. 3840A
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
192.0 .. 3200A
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Number of poles
3
With switched-off indicator
Type of control element
Toggle
Overload release current setting
128.0 .. 320A
Degree of protection (IP)
IP20
Motor drive integrated
Motor drive optional
Rated permanent current Iu
400A
From same serie