Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
2000A
Overload release current setting
800.0 - 2000A
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Rated voltage
1000 - 1000V
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
No
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Integrated earth fault protection
No
Complete device with protection unit
Yes
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA069475R1 | E3H/VF 2000 PR122VF In2000A 3p W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
2000A
Overload release current setting
800.0 .. 2000A
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Rated voltage
1000 .. 1000V
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Integrated earth fault protection
Complete device with protection unit
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
From same serie