Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
1200A
Rated voltage
1000 - 1000V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Overload release current setting
480.0 - 1200A
Adjustment range undelayed short-circuit release
1800.0 - 18000A
Power loss
120W
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
With integrated under voltage release
No
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA069473R1 | E2N/VF 1200 PR122VF In1200A 3p WMP 1000V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
1200A
Rated voltage
1000 .. 1000V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Overload release current setting
480.0 .. 1200A
Adjustment range undelayed short-circuit release
1800.0 .. 18000A
Power loss
120W
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
With integrated under voltage release
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie