Aleta.hr
Main Product Image

2CDS274061R0408 | S204M-Z8UC

Code: 1617901

ManufacturerRAZNO
Catalog number2CDS274061R0408
Type
EAN code4013614437854

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Release characteristic

Z

Number of poles (total)

4

Rated current

8A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Pollution degree

3

Current limiting class

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Built-in depth

69mm

Voltage type

AC/DC

Ambient temperature during operating

-25 - 55°C

Frequency

50 - 60Hz

Suitable for flush-mounted installation

No

Additional equipment possible

Yes

Connectable conductor cross section multi-wired

0 - 25mm²

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 - 35mm²

Width in number of modular spacings

4


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS274061R0408 | S204M-Z8UC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Release characteristic

Z

Number of poles (total)

4

Rated current

8A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Pollution degree

3

Current limiting class

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Built-in depth

69mm

Voltage type

AC/DC

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 35mm²

Width in number of modular spacings

4