Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
375.0 - 3750A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
250A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Rated voltage
690 - 690V
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Motor drive integrated
No
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Overload release current setting
100.0 - 250A
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
From same serie
1SDA073661R1 | E2.2S 250 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
250A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Rated voltage
690 .. 690V
Type of control element
Push button
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Complete device with protection unit
Motor drive integrated
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Overload release current setting
100.0 .. 250A
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
From same serie