Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
250A
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
375.0 - 3750A
Number of auxiliary contacts as normally open contact
0
Overload release current setting
100.0 - 250A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Motor drive optional
Yes
Number of poles
4
Position of connection for main current circuit
Back side
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073647R1 | E2.2S 250 EKIP G HI-TOUCH LSIG 4

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
250A
Rated voltage
690 .. 690V
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Number of auxiliary contacts as normally open contact
0
Overload release current setting
100.0 .. 250A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Motor drive optional
Number of poles
4
Position of connection for main current circuit
Back side
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie
We use cookies to enhance your experience.