Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Type of control element
Push button
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Interlockable
No
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Version as main switch
Yes
Version as safety switch
No
Version as reversing switch
No
Version as maintenance-/service switch
No
Number of switches
0
Max. rated operation voltage Ue AC
690V
Version as emergency stop installation
No
Rated permanent current at AC-23, 400 V
1600A
Rated operating voltage
690 - 690V
Rated short-time withstand current lcw
66kA
Rated permanent current Iu
1600A
Number of poles
4
Rated permanent current at AC-21, 400 V
1600A
Motor drive integrated
No
Voltage release optional
Yes
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Suitable for front mounting 4-hole
No
Motor drive optional
Yes
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Colour control element
Other
Suitable for intermediate mounting
No
Degree of protection (IP), front side
IP30
Type of electrical connection of main circuit
Bolt connection
Degree of protection (NEMA)
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073448R1 | E2.2N/MS 1600 4P FHR

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Type of control element
Push button
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Interlockable
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Version as main switch
Version as safety switch
Version as reversing switch
Version as maintenance-/service switch
Number of switches
0
Max. rated operation voltage Ue AC
690V
Version as emergency stop installation
Rated permanent current at AC-23, 400 V
1600A
Rated operating voltage
690 .. 690V
Rated short-time withstand current lcw
66kA
Rated permanent current Iu
1600A
Number of poles
4
Rated permanent current at AC-21, 400 V
1600A
Motor drive integrated
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Suitable for front mounting 4-hole
Motor drive optional
Suitable for front mounting centre
Suitable for distribution board installation
Colour control element
Other
Suitable for intermediate mounting
Degree of protection (IP), front side
IP30
Type of electrical connection of main circuit
Bolt connection
Degree of protection (NEMA)
Other