Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Interlockable
No
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Version as safety switch
No
Version as main switch
Yes
Version as reversing switch
No
Max. rated operation voltage Ue AC
690V
Version as emergency stop installation
No
Rated operating voltage
690 - 690V
Version as maintenance-/service switch
No
Rated permanent current Iu
1600A
Rated permanent current at AC-21, 400 V
1600A
Motor drive optional
Yes
Rated permanent current at AC-23, 400 V
1600A
Rated short-time withstand current lcw
66kA
Number of poles
3
Motor drive integrated
No
Voltage release optional
Yes
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
No
Suitable for front mounting centre
No
Colour control element
Other
Suitable for distribution board installation
Yes
Type of electrical connection of main circuit
Bolt connection
Type of control element
Push button
Degree of protection (IP), front side
IP30
Degree of protection (NEMA)
Other
From same serie
1SDA073409R1 | E2.2N/MS 1600 3P FHR

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Interlockable
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Version as safety switch
Version as main switch
Version as reversing switch
Max. rated operation voltage Ue AC
690V
Version as emergency stop installation
Rated operating voltage
690 .. 690V
Version as maintenance-/service switch
Rated permanent current Iu
1600A
Rated permanent current at AC-21, 400 V
1600A
Motor drive optional
Rated permanent current at AC-23, 400 V
1600A
Rated short-time withstand current lcw
66kA
Number of poles
3
Motor drive integrated
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Suitable for front mounting centre
Colour control element
Other
Suitable for distribution board installation
Type of electrical connection of main circuit
Bolt connection
Type of control element
Push button
Degree of protection (IP), front side
IP30
Degree of protection (NEMA)
Other