Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Overload release current setting
2520.0 - 6300A
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
3780.0 - 63000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
6300A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Yes
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Motor drive integrated
No
Type of control element
Push button
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA073380R1 | E6.2V/F 6300 EKIP G HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Overload release current setting
2520.0 .. 6300A
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
3780.0 .. 63000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
6300A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Motor drive integrated
Type of control element
Push button
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional