Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
2520.0 - 6300A
Motor drive optional
Yes
Complete device with protection unit
Yes
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Yes
Motor drive integrated
No
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
3780.0 - 63000A
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073369R1 | E6.2H/F 6300 EKIP HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 .. 690V
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
2520.0 .. 6300A
Motor drive optional
Complete device with protection unit
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Motor drive integrated
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
3780.0 .. 63000A
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
From same serie