Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 - 690V
Integrated earth fault protection
No
Overload release current setting
2520.0 - 6300A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
With switched-off indicator
Yes
Number of poles
4
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive optional
Yes
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
6300A
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
9450.0 - 94500A
From same serie
1SDA073364R1 | E6.2H/F 6300 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 .. 690V
Integrated earth fault protection
Overload release current setting
2520.0 .. 6300A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Motor drive integrated
With switched-off indicator
Number of poles
4
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
6300A
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
From same serie