Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
5000A
Integrated earth fault protection
Yes
Overload release current setting
2000.0 - 5000A
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Complete device with protection unit
Yes
With switched-off indicator
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
From same serie
1SDA073246R1 | E6.2H 5000 EKIP TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
5000A
Integrated earth fault protection
Overload release current setting
2000.0 .. 5000A
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Complete device with protection unit
With switched-off indicator
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional
From same serie