Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1600.0 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
4000A
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Type of control element
Push button
Number of poles
4
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Motor drive optional
Yes
Rated voltage
690 - 690V
From same serie
1SDA073211R1 | E6.2H 4000 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1600.0 .. 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
4000A
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Type of control element
Push button
Number of poles
4
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Motor drive optional
Rated voltage
690 .. 690V