Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Overload release current setting
1600.0 - 4000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
4000A
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
With under voltage release
No
Degree of protection (IP)
IP30
Type of control element
Push button
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073204R1 | E4.2V 4000 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Overload release current setting
1600.0 .. 4000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
4000A
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
With under voltage release
Degree of protection (IP)
IP30
Type of control element
Push button
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
From same serie