Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
4000A
Rated voltage
690 - 690V
Overload release current setting
1600.0 - 4000A
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
No
With switched-off indicator
Yes
With under voltage release
No
Number of poles
4
Type of control element
Push button
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
From same serie
1SDA073188R1 | E4.2S 4000 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
4000A
Rated voltage
690 .. 690V
Overload release current setting
1600.0 .. 4000A
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
With switched-off indicator
With under voltage release
Number of poles
4
Type of control element
Push button
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
From same serie
We use cookies to enhance your experience.