Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
4000A
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
6000.0 - 60000A
With switched-off indicator
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Overload release current setting
1600.0 - 4000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA073172R1 | E4.2N 4000 EKIP DIP LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
4000A
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Overload release current setting
1600.0 .. 4000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie