Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
1280.0 - 3200A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Rated permanent current Iu
3200A
Complete device with protection unit
Yes
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Motor drive optional
Yes
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Integrated earth fault protection
Yes
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
With switched-off indicator
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073127R1 | E4.2N 3200 EKIP G TOUCH LSIG 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
1280.0 .. 3200A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Rated permanent current Iu
3200A
Complete device with protection unit
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Motor drive optional
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Integrated earth fault protection
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
With switched-off indicator
From same serie