

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
2000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Overload release current setting
800.0 - 2000A
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Yes
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073089R1 | E4.2V 2000 EKIP HI-TOUCH LSIG 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
2000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Overload release current setting
800.0 .. 2000A
Type of control element
Push button
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
From same serie
We use cookies to enhance your experience.