Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
With switched-off indicator
Yes
Number of poles
4
Type of control element
Push button
Rated permanent current Iu
2500A
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
No
Motor drive optional
Yes
Overload release current setting
1000.0 - 2500A
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073050R1 | E2.2N 2500 EKIP G HI-TOUCH LSIG

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
With switched-off indicator
Number of poles
4
Type of control element
Push button
Rated permanent current Iu
2500A
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
Motor drive optional
Overload release current setting
1000.0 .. 2500A
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
From same serie