Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Overload release current setting
800.0 - 2000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
With switched-off indicator
Yes
Complete device with protection unit
Yes
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA073003R1 | E2.2B 2000 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Overload release current setting
800.0 .. 2000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
With switched-off indicator
Complete device with protection unit
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie