Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Overload release current setting
640.0 - 1600A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
Number of poles
4
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
From same serie
1SDA072997R1 | E2.2H 1600 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Overload release current setting
640.0 .. 1600A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
DIN rail (top hat rail) mounting optional
Number of poles
4
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
From same serie