Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
1600A
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
640.0 - 1600A
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Complete device with protection unit
Yes
Number of auxiliary contacts as normally closed contact
0
From same serie
1SDA072983R1 | E2.2S 1600 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
1600A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
640.0 .. 1600A
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Complete device with protection unit
Number of auxiliary contacts as normally closed contact
0
From same serie