Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Overload release current setting
640.0 - 1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Number of poles
4
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive integrated
No
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
With under voltage release
No
Complete device with protection unit
Yes
From same serie
1SDA072978R1 | E2.2N 1600 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Overload release current setting
640.0 .. 1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Number of poles
4
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive integrated
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Degree of protection (IP)
IP30
With under voltage release
Complete device with protection unit