Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Overload release current setting
640.0 - 1600A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
1600A
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 - 24000A
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Motor drive integrated
No
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072966R1 | E2.2B 1600 EKIP TOUCH LSIG 4P WM

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Overload release current setting
640.0 .. 1600A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
1600A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Motor drive integrated
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Complete device with protection unit
Motor drive optional
From same serie
We use cookies to enhance your experience.