

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
1250A
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 - 1250A
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
From same serie
1SDA072949R1 | E2.2S 1250 EKIP HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
1250A
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
500.0 .. 1250A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Motor drive integrated
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
From same serie
We use cookies to enhance your experience.