Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
500.0 - 1250A
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Rated voltage
690 - 690V
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072938R1 | E2.2N 1250 EKIP HI-TOUCH LSI 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
500.0 .. 1250A
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
DIN rail (top hat rail) mounting optional
Motor drive optional
With switched-off indicator
Degree of protection (IP)
IP30
Complete device with protection unit
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
From same serie