Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Overload release current setting
400.0 - 1000A
Number of poles
4
Integrated earth fault protection
Yes
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Complete device with protection unit
Yes
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072923R1 | E2.2H 1000 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Overload release current setting
400.0 .. 1000A
Number of poles
4
Integrated earth fault protection
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Complete device with protection unit
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
From same serie