

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated voltage
690 - 690V
Rated permanent current Iu
1000A
Overload release current setting
400.0 - 1000A
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Motor drive integrated
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Motor drive optional
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Number of poles
4
From same serie
1SDA072919R1 | E2.2S 1000 EKIP HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated voltage
690 .. 690V
Rated permanent current Iu
1000A
Overload release current setting
400.0 .. 1000A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Motor drive integrated
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Motor drive optional
Type of control element
Push button
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Number of poles
4
From same serie
We use cookies to enhance your experience.