

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1000A
Rated voltage
690 - 690V
Overload release current setting
400.0 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Motor drive optional
Yes
With switched-off indicator
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072915R1 | E2.2S 1000 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1000A
Rated voltage
690 .. 690V
Overload release current setting
400.0 .. 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Motor drive optional
With switched-off indicator
From same serie
We use cookies to enhance your experience.