

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 - 690V
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 - 12000A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
320.0 - 800A
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Yes
Number of poles
4
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Yes
Motor drive integrated
No
From same serie
1SDA072891R1 | E2.2H 800 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 .. 690V
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
320.0 .. 800A
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Number of poles
4
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Motor drive integrated
From same serie
We use cookies to enhance your experience.