Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
800A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Overload release current setting
320.0 - 800A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072883R1 | E2.2S 800 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
800A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30
Overload release current setting
320.0 .. 800A