Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
800A
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Overload release current setting
320.0 - 800A
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Number of poles
4
Type of control element
Push button
Motor drive optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072882R1 | E2.2S 800 EKIP DIP LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
800A
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Overload release current setting
320.0 .. 800A
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Number of poles
4
Type of control element
Push button
Motor drive optional
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection