Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Overload release current setting
320.0 - 800A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
With switched-off indicator
Yes
Type of control element
Push button
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Suitable for DIN rail (top hat rail) mounting
No
With under voltage release
No
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Yes
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Degree of protection (IP)
IP30
Rated voltage
690 - 690V
From same serie
1SDA072878R1 | E2.2N 800 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Overload release current setting
320.0 .. 800A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
With switched-off indicator
Type of control element
Push button
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Suitable for DIN rail (top hat rail) mounting
With under voltage release
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Degree of protection (IP)
IP30
Rated voltage
690 .. 690V